Products

CO2 Cascade Systems

FRICO2 Sub-Critical Cascade refrigeration systems have been designed for large supermarkets and hypermarkets having in mind efficiency and reliability.



Environmentally Friendly

Certified Products

Energy Saving

Tag: Split Refrigeration Systems

Share:

FRICO2 Sub-Critical Cascade refrigeration systems have been designed for large supermarkets and hypermarkets having in mind efficiency and reliability. It is the answer to environmental concerns as it combines low energy consumption and the use of the natural refrigerant CO2. FRICO2 is a protection of investment against cost increase and legislations upon not using synthetic refrigerants. System provides refrigeration capacities for wide range of applications for different temperature ranges. FRICO2 is designed for both Medium and Low Temperature applications. Also combined MT and LT models are available. Compact frame allows for fast installation and stable platform for superior performance and durability.

Using CO2 in cascade systems gives a number of advantages:

  • 1

    Efficiency of the system is high even in the hot climates

  • 2

    Only a small amount of refrigerant is needed for high temperature stage

  • 3

    Temperature difference for cascade heat exchanger is relatively low

  • 4

    On the high side various refrigerants can be used ex HC/ HFC or NH3.

  • 5

    Lower First Cost

  • 6

    Less space required

  • 7

    Lower temperatures at reasonable costs

  • 8

    CO2 is non‐toxic and non‐flammable

  • 9

    CO2 does not damage products

  • 10

    CO2 Cascade Systems reduce CO2 emission

Using CO2 in cascade systems gives a number of advantages:

  • 1

    Efficiency of the system is high even in the hot climates

  • 2

    Only a small amount of refrigerant is needed for high temperature stage

  • 3

    Temperature difference for cascade heat exchanger is relatively low

  • 4

    On the high side various refrigerants can be used ex HC/ HFC or NH3.

  • 5

    Lower First Cost

  • 6

    Less space required

  • 7

    Lower temperatures at reasonable costs

  • 8

    CO2 is non‐toxic and non‐flammable

  • 9

    CO2 does not damage products

  • 10

    CO2 Cascade Systems reduce CO2 emission

DESIGN DATA

MODEL No. Of Compr.
HTC + LTC
Q brine
(kW)
Q DX
(kW)
P total, nom
(kW)
Evap. Temp.
(OC)
Comp. Type Pump Type
CP-CS 1 23-77 - 9.5-40 -10 BOCK LEDERLE
2X RACK / CP-CRS 2 38-154 - 9.5-43 -10 BOCK LEDERLE HERMETIC
CC-FS 2 + 1 - 5-140 2.75-96 -25 BOCK -
2X RACK/CC-FRS 2+2 - 12-290 5.8-191.8 -25 BOCK -
CC-FG/FS 2+1 - 3-85 2.42-64.9 -40 BOCK -
CCP-CS/FS 4+1 75 25 60 -25/-10 BOCK LEDERLE HERMETIC